AG Equipment
Rental and Consulting
|
|
|
|
|

|
Cooling
Capacity BTU/h 10,000
Airflow CFM
270
Electrical
Requirements 115V, 1 phase
Current
Consumption (Amps) 10.6
Dimensions
HxDxW (In.) 41x26x19
Net
Wt./Shipping Wt. (lbs) 145/170
Operating
Conditions 68-105 F
Humidity
Removed at 95F at 60% RH 1.25 gal/hr
Drain Tank
Capacity 5.0 gal
Sound Level
w/Duct 55 dB
Approximate
Operating Cost 11¢ per hour
|

|
Cooling
Capacity BTU/h 11,800
Airflow CFM
410/380
Electrical
Requirements 115V, 1 phase
Current
Consumption (Amps) 11.2
Dimensions
HxDxW (In.) 44x27x21
Net Wt. /
Shipping Wt. (lbs) 165/195
Operating
Conditions 65-95 F
Humidity
Removed at 95F at 60% RH 1.17 gal/hr
Drain Tank
Capacity 5.0 gal Sound
Level w/Duct
(High/Low) 52/50 dB
Approximate
Operating Cost 14¢ per hour
|
|

|
|

|
|

|
|

|
|

|
|

|
|

|
Applications:
|
|
|
|
|
Applications:
Computer
Rooms
Labratory
Cooling
Electronic
Equipment
Telephone
Switch Gear
Communication
Centers
Server
Racks and Closets
|
|
|

|
|
|
|
|
|
|
|
|
|

|
Cooling
Capacity BTU/h 13,200
Airflow CFM
440/380
Electrical
Requirements 115V, 1 phase
Current
Consumption (Amps) 12.3
Dimensions
HxDxW (In.) 41x26x19
Net
Wt./Shipping Wt. (lbs) 153/195
Operating
Conditions 70-113 F
Humidity
Removed at 95F at 60% RH 1.33 gal/hr
Drain Tank
Capacity 5.0 gal Sound
Level w/Duct
(High/Low) 57/55 dB
Approximate
Operating Cost 13¢ per hour
|

|
Cooling
Capacity BTU/h 18,000
Airflow CFM
530
Electrical
Requirements 208/230V, 1 phase
Current
Consumption (Amps) 10.8/10.0
Dimensions
HxDxW (In.) 47x26x19
Net
Wt./Shipping Wt. (lbs) 167/200
Operating
Conditions 68-105 F
Humidity
Removed at 95F at 60% RH 1.92 gal/hr
Drain Tank
Capacity 5.0 gal Sound
Level w/Duct
(High/Low) 63 dB
Approximate
Operating Cost 20¢ per hour
|
|
|
|
|
|
|
Applications:
|
|
|
|
|
Applications:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

|
Cooling
Capacity BTU/h 16,800
Airflow CFM
540/500
Electrical
Requirements 115v, 1 phase
Current
Consumption (Amps) 15.6
Dimensions
HxDxW (In.) 44x27x21
Net
Wt./Shipping Wt. (lbs) 177/207
Operating
Conditions 65-95 F
Humidity
Removed at 95 at 60% RH 1.92 gal/hr
Drain Tank
Capacity 5 gal
Sound Level
w/Duct (High/Low) 61/59 dB
Approximate
Operating Cost 17¢ per hour
|

|
Cooling
Capacity BTU/h 23,300
Airflow CFM
630/545
Electrical
Requirements 208/230V, 1 phase
Current
Consumption (Amps) 11.2
Dimensions
HxDxW (In.) 47x27x21
Net
Wt./Shipping Wt. (lbs) 210/250
Operating
Conditions 65-95 F
Humidity
Removed at 95F at 60% RH 2.5 gal/hr
Drain Tank
Capacity 5.0 gal
Sound Level
w/Duct (High/Low) 63/61 dB
Approximate
Operating Cost 22¢ per hour
|
|
|
|
|
|
|
Applications:
Control
Panels
Computer
Rooms
Electronic
Equipment
Telephone
Switch Gear
Communication
Centers
Server
Racks and Closets
|
|
|
|
Applications:
Control
Panels
Computer
Rooms
Electronic
Equipment
Telephone
Switch Gear
Communication
Centers
Server
Racks and Closets
|
|
|
|
|
|

|
Cooling
Capacity BTU/h 24,000
Airflow CFM
708/600
Electrical
Requirements 208/230V, 1 phase
Current
Consumption (Amps) 15.6/14.0
Dimensions
HxDxW (In.) 47x29x19
Net
Wt./Shipping Wt. (lbs) 235/265
Operating
Conditions 70-113 F
Humidity
Removed at 95F at 60% RH 2.33 gal/hr
Drain Tank
Capacity 5.0 gal
Sound Level
w/Duct (High/Low) 66/64 dB
Approximate
Operating Cost 31¢ per hour
|

|
Cooling
Capacity BTU/h 36,000
Airflow
CFM 990/825
Electrical
Requirements 208/230V, 1 phase
Current
Consumption (Amps) 19.7
Dimensions
HxDxW (In.) 52x44x30
Net
Wt./Shipping Wt. (lbs) 440/540
Operating
Conditions 65-95 F
Humidity
Removed at 60% RH
Drain
Tank Capacity
2 @ 5 gal
Sound
Level w/Duct (High/Low)
65/62 dB
Approximate
Operating Cost
44¢ per
hour
|
|
|
|
Applications:
|
|
|
|
Applications:
Control
Panels
Computer
Rooms
Electronic
Equipment
Telephone
Switch Gear
Communication
Centers
Server
Racks and Closets
|
|
|
|
|
|

|
Cooling
Capacity BTU/h 39,000
Airflow CFM
1,060
Electrical
Requirements 220V, 3 phase
Current
Consumption (Amps) 14.0
Dimensions
HxDxW (In.) 39x43x26
Net
Wt./Shipping Wt. (lbs) 353/420
Operating
Conditions 75-115 F
Humidity
Removed at 95 F at 60% RH 5.8 gal/hr
Drain Tank
Capacity 2 @ 5 gal (optional)
Sound Level
without Duct 72 dB
Approximate
Operating Cost 47¢ per hour
|

|
Cooling
Capacity BTU/h 60,000
Airflow CFM
1,580
Electrical
Requirements 460V, 3 phase
Current
Consumption (Amps) 10.5
Dimensions
HxDxW (In.) 42x49x32
Net
Wt./Shipping Wt. (lbs) 463/545
Operating
Conditions 75-115 F
Humidity
Removed at 95F at 60% RH 7.67 gal/hr
Drain Tank
Capacity N/A
Sound Level
without Duct 72 dB
Approximate
Operating Cost 72¢ per hour
|
|
|
|
Applications:
|
|
|
|
Applications:
|
|
|
|
|
|

|
Cooling
Capacity BTU/h 59,500
Airflow CFM
1940/1770
Electrical
Requirements 208/230V, 1 phase
Current
Consumption (Amps) 33 Dimensions
HxDxW (In.) 64x52x30
Net Wt. /
Shipping Wt. (lbs) 625/755
Operating
Conditions 65-105 F
Humidity
Removed at 95F at 60% RH 3.92 gal/hr
Drain Tank
Capacity N/A
Sound Level
w/Duct (High/Low) 69/67 dB
Approximate
Operating Cost 71¢ per hour
|
|
|
|
|
|
|
|
|
Applications:
Control
Panels
Computer
Rooms
Electronic
Equipment
Telephone
Switch Gear
Communication
Centers
Server
Racks and Closets
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|